wonderiop.blogg.se

Viscosity cups
Viscosity cups






viscosity cups
  1. #Viscosity cups series
  2. #Viscosity cups free

During the flow time, hold the cup no more than 6” above the level of the sample material. In a quick, steady motion, lift the cup out of the sample material, starting the timer when the top edge of the cup breaks the surface.

  • Hold cup vertically by inserting index finger into handle ring.
  • Measure and record the temperature of the material that is encompassed by the cup.
  • viscosity cups

    #Viscosity cups free

    Completely immerse the cup into the material to be measured in a location free from bubbles or foam, holding the cup vertically by means of the stainless steel split key ring.Adjust the temperature, if necessary, of the test material.Insure that the cup is clean and that there is no residual dried material in or around the orifice.Select the proper number cup to be used from the Specification Table, which is dependent on the expected viscosity range of the material to be measured.Following this table are graphs and mathematical formulas that relate efflux time in seconds to centistoke viscosity. The following table provides operating range specifications, dip cup midrange sensitivity and recommended Canon calibration oils (standards). All parts of the flow cup are of stainless steel except for the name plate. Such equipment not only insures that each cup is correctly produced but also that all cups are identical. The EZ™ Viscosity Cups are produced to very close mechanical tolerance in elaborate jigs and fixtures. This document contains not only information on actual cup calibration with standard oils traceable to the National Institute of Standards and Technology but in addition, this certification also complies to conditions and procedures under the requirements of ANSI/NCSL Z540 or ISO/IEC 17025 as applicable. This table is particularly useful in determining efflux time in seconds when viscosity in centistokes is known.įor those users who require documented certification of their measuring equipment, the EZ™ dip cups may be ordered, at an additional charge, with a CERTIFICATE of CALIBRATION. Not only has this cup been improved with respect to earlier produced cups and designed to comply to the requirements of ASTM D4212 but, in addition, each EZ Viscosity Dip Cup is furnished with a table which permits conversion between efflux time in seconds to the nearest tenth of a second to viscosity in centistokes.

    #Viscosity cups series

    The EZ Viscosity Cup Series is a logical and necessary outgrowth of the standardization studies on the Zahn Signature Viscosity Cup and similar cups for the promotion of this most popular type of viscosity measuring instrument as a national and international standard.

  • The increased separation width of the support rods by over 20% and the lowering of weld to the cup provide best possible conditions for cleaning.
  • This eliminates errors due to test material drainage from support surfaces.
  • The EZ Viscosity Cup support rods are offset from the side of the cup and secured to the cup sidewall below the cup rim.
  • This insures an orifice of specified length and a correct symmetrical efflux stream.
  • EZ Dip Cup orifices are machined rather than drilled to insure exact centering in the cup hemisphere base and a minimum of burr formation.
  • Conversion table relating efflux time in seconds, to the nearest tenth of a second, to viscosity in centistokes furnished with each EZ™ Dip Cup.
  • 3% guaranteed tolerance for EZ Viscosity Cups complies with & exceeds ASTM D4212.
  • Calibration and Certification procedures qualify under ISO/IEC 17025 as applicable.
  • EZ Viscosity Cup calibration is traceable to the National Institute of Standards and Technology (NIST).
  • EZ Viscosity Dip Cups are compatible to ASTM D1084 Viscosity of Adhesives and ASTM D816.
  • viscosity cups

    The EZ Flow Cup formula for each cup of the series matches the applicable ASTM formula in D4212 at the recommended calibration level.More information can be found in our EZ Viscosity Cup Manual. All EZ Viscosity Cups are made of stainless steel and are calibrated at our Gardco Service Department. It is not matched by any other dip cup of its type, either with respect to the advantages listed below, in highest quality of workmanship or in continuing quality control procedures. The EZ Zahn Viscosity Dip Cup is the finest, most reliable, ASTM calibrated & documented viscosity cup on the market. Home > Products > Viscosity > EZ Zahn Viscosity Cups








    Viscosity cups